AW-B3000 Barrel Batch Plasma Asher Descum Equipment
Company Information:
Name: |
AW-B3000 Barrel Batch Plasma Asher Descum Equipment |
Category: |
|
Offered by: |
|
AW-B3000 Barrel Batch Plasma Asher Descum Equipment Description:
sales@allwin21.com
The AW-B3000 batch/barrel photoresist asher is a manual load tool designed as a flexible 13.56 MHz RF plasma photoresist removal system for high-volume wafer fabrication. The AW-B3000 is in direct response to manufacturer’s concerns for Uptime, Reliability, Production-Proven technology. and low cost of ownership. .
Key Features:
- Production-proven plasma Stripper/Asher/Descum technology.
- Up to 25% Uniformity. Much lower if used with a Faraday Cage.
- Consistent wafer-to-wafer uniformity.
- TC Option can be used with an N2 Plasma to heat the wafers up to 170°C (Chamber) to increase ash rate.
- End-of-Process (EOP) Option automatically stops the Process after all wafers are fully stripped regardless of wafer quantity or photoresist thickness.
- Samples, 6” square, and up to 8” round wafers capable.
- Many wafer sizes capability without hardware change.
- Can handle different thickness wafer with different carriers.
- New controller with PC with Advanced AW Software
- Up to 5 isolated gas lines with MFC’s
- 13.56 MHz RF Generator. (Air-cooled Optional)
- Pressure Control Throttle Valve for better process repeatability. (Optional)
- MKS Baratron (Optional)
- Touch screen GUI
- EMO, Interlocks and Watchdog function
- GEM/SECS II (Optional)
- Made in U.S.A.
Software Features:
- Integrated process control system
- Real time graphics display
- Real time process data acquisition, display, and analysis
- Programmed comprehensive calibration and diagnostic functions
- Closed-loop temperature control with temperature sensing.
- Precise time-temperature profiles tailored to suit specific process requirements.
- Faster, easier Programmable comprehensive calibration of all subsystems, leading to enhanced process results.
- A recipe editor to create and edit recipes to fully automate the processing of wafers inside the AccuThermo RTP
- Validation of the recipe so improper control sequences will be revealed.
- Storage of multiple recipes, process data and calibration files so that process and calibration results can be maintained and compared over time.
- Passwords provide security for the system, recipe editing, diagnostics, calibration and setup functions.
- Simple and easy to use menu screen which allow a process cycle to be easily defined and executed.
- Troubleshooting feature which allows engineers and service personnel to activate individual subassemblies and functions. More I/O, AD/DA “exposure”.
- Use PowerSum technology to detect the process and increase Yield.
- Watchdog function: If this board looses communication with the control software, it will shut down all processes and halt the system until communication is restored.
- GEM/SECS II function (Optional).
Configuration:
- Main Body with wires
- Control Box
- Pentium Class PC with AW Software
- Keyboard, Mouse, USB with SW backup and Cables
- Main Control PCB and DC
- Transformer, Circuit Breaker,Contactor
- 1-5 Isolated Gas Lines w/ Pneumatic Valve and MFC
- Purge has manual regulator in controller box to control speed.
- Quartz Chamber:Dia 12” x Depth 23”;
- RF Match Network Integrated in the Main Body of tool.
- Chamber Door with quartz plate in the Main Body.
- Gas and vacuum lines Connections in the Main Body
- 13.56MHz RF Generator (Air-Cooled is Optional) : ① 300W; ② 600W; ③ 1000W; ④ 1200W
- Lamp tower alarm with buzzer
- Main Vacuum Valve
- MKS Baratron
- Throttle Valve
- Front EMO, Interlocks
- 15-inch Touch Screen GUI
Options:
- End-of-Process (EOP) function.
- Throttle Valve for pressure control.
- Air-cooled RF Generator.
- GEM/SECS II function (Software)
- Thermocouple for Chamber Temperature
- Vacuum Pump
Specifications:
- Wafer Size: Sample to 200mm Capability. Multiple wafer size without hardware change
- High Throughput: Up to 75 WPH. Process Dependent.
- Temperature: Only TC Option can be used for N2 plasma to heat the substrates up to 170°C.
- Gas Lines: Up to 5 isolated gas lines with MFCs.
- Asher Rate: 0-0.1u/min. positive PR; >0.2u/min. negative PR. Slower if Faraday Cage is used
- Uniformity: Up to 25%. Much lower with Faraday Cage.
- Particulate: <0.05 /cm2 (0.03um or greater)
- Damage: Low damage with Faraday Cage.
- Selectivity: >1000:1
- MTBF/MTTA/MTTR: 450 Hours/100 Hours/3.5 Hours or Better.
- 95% uptime
- * Contact Allwin21 sales for other applications and specifications.
sales@allwin21.com
AW-B3000 Barrel Batch Plasma Asher Descum Equipment was added in Nov 2015
AW-B3000 Barrel Batch Plasma Asher Descum Equipment has been viewed 447 times