1. Our Advantages
1.1. Japan Hamamatsu X-ray tube, the best closed type X-ray tube in the world, with the longest lifetime and maintenance-free.
1.2 New generation Korea Rayence HD digital flat panel detector (FPD), eliminate the image intensifier.
1.3. Automatic navigation window, table will move to where you click.
1.4. 420*420mm table with 15KG load capacity.
1.5. Speed adjustable 3 axis linkage system.
1.6. Can edit inspection procedures to achieve automated inspection in large quantities.
1.7. 360° rotary jig optional, can inspect product from different angles.
1.8. Easy to operate, can quickly find defects, only need 2 hours to train.
2. Hardware Parameters
X-ray source |
Brand |
Japan Hamamatsu |
|
Type |
Closed, microfocus |
||
Max tube voltage |
90kV |
||
Max tube current |
200μA |
||
Focal spot size |
5μm |
||
Function |
Auto preheat |
||
Flat panel detector |
Brand |
Korea Rayence |
|
Effective area |
58mm*54mm |
||
Pixel size |
49.5μm |
||
Resolution |
1176*1104 |
||
Frame rate |
30fps |
||
Table |
Size |
420mm*420mm |
|
Detectable area |
400mm*400mm |
||
Max load |
15kg |
||
Equipment |
Magnification |
Geometry 200X |
System 1500X |
Inspection speed |
Max 3.0s/point |
||
Dimensions |
1100mm (L) * 1000mm (W) * 1600mm (H) |
||
Weight |
1000kg |
||
Power supply |
AC110-220V 50/60HZ |
||
Max power |
1300W |
||
Industrial PC |
I3-7100 CPU, 4G RAM, 240GB SSD |
||
Displayer |
24” HDMI LCD |
||
Safety |
Radiation leakage |
No leakage, international standard: ≤1μSv/h |
|
Lead glass observation window |
Transparent lead glass window shields radiation to observe the inner status. |
||
Window and back door safety interlock |
Once users open the window or back door, X-ray tube will power off immediately. When the window or back door is open, users can’t turn on the X-ray. |
||
Electromagnetic safety switch |
Lock once the X-ray is on, users can’t open the observation window. |
||
Emergency stop |
Next to the operation position, press to power off |
||
Tube protection |
User can't leave the software to if you don't close the X-ray tube. |
3.Contacts
Shenzhen Weiming Photoelectricity Co, Ltd
Add: No.5, Jinyuan 2nd Road, Xinqiao Community, Xinqiao Street, Bao'an, Shenzhen
Web: www.well-man.com
Tel: +86-0755-22289778
WeChat/WhatsApp/Skype/Mob: +86-1840-6666-351
Email: sales8@well-man.com
X-Ray Inspection System X6000 was added in Sep 2019
X-Ray Inspection System X6000 has been viewed 161 times
9 More Products from Shenzhen Weiming Photoelectricity Co, Ltd :