Sencore LC103

Sencore LC103

Sencore LC103

Model:

Sencore LC103

Category:

In-Circuit Testers

Condition:

used

Location:

Florida, USA

Offered by:

Test Equipment Connection

   
  Contact Supplier

Sencore LC103

LC103 Condensed Specifications

IN-CIRCUIT TESTS (Capacitors and Inductors):
- Dynamic in-circuit tests to determine whether the component is good or bad. Component Types: Electrolytic, double layer lytic, tantalum, ceramic, and other capacitors.
   Yokes, flybacks, switching transformers, and coils. Inductor Range: 3.18 uH to 3.18 H
Capacitor Range: 0.002 uF to 20,000 uF
Accuracy: Same as Out-of-Circuit tests for known good inductors and capacitors with no parallel    current paths.
Suggest Removal Indication: Initiated when AC test differs from DC test by more than 20%, or if low level DCR test indicates a leakage path greater than 20% of charge current for capacitors.

CAPACITORS (Out-of-Circuit):
Value: Dynamic test of capacity value is determined by applying a constant current to the capacitor and measuring the dV/dt.
Range: 1 pF to 20 F
Accuracy: ±1%, ±1 pF, ±1 digit for values to 1990 uF, ±5%; 0.1% of range full scale for values 2000 uF to 20 F

EQUIVALENT SERIES RESISTANCE (ESR):
Accuracy: ±5%, ±1 digit
Capacitor Range: 0.01 uF to 20 F

DIELECTRIC ABSORPTION:
Accuracy: ±5% of reading, ±1 count
Range: 1 to 100%
Capacitor Range: 0.01 uF to 20 F

LEAKAGE:
Accuracy: ±5%, ±1 digit
Applied Voltage: Keyboard entry 1.0 to 1000 volts in 0.1 volt steps short circuit current limited to 900 mA

INDUCTORS (Out-of-Circuit):
Value: A dynamic test of value determined by measuring the EMF produced when a changing current
   is applied to the coil under test
Range: 0.1 uH to 20 H
Accuracy: ±2%, ±1 digit, ±0.1 uH

RINGING TEST:
- A dynamic test of inductor quality determined by applying an exciting pulse to the inductor and counting the number of cycles the inductor rings before reaching a preset damping point.
Inductor Range: 10 uH and larger, non-iron core
Accuracy: ±1 count on readings between 8 and 13 Rings Resolution: ±1 count
Exciting Pulse: 5 volts peak

GENERAL:
Temperature Operating Range: 32¡ to 104¡ F (0¡ to 40¡ C)
Temperature Range for Specified Accuracy (after 10 minute warm-up): 50¡ to 86¡ F (10¡ to 30¡ C)
Power: 105-130V AC, 60Hz, 30 watts with supplied PA251 power adapter.
   Battery operation with optional BY289 rechargeable battery.
Auto-Off: Removes power during battery operation if unit sits idle longer than 5 minutes.
Battery Life: 2 hours typical operation
HxWxD Size: 6" x 9" x 11.5" (15.2 cm x 22.9 cm x 29.l cm)
Weight: 6.0 lbs. (2.7 kg) without battery, 7.6 lbs. (3.4 kg) with battery
GOOD/BAD Indication: Functions on all tests.
   Requires user input of component type and value, or input of desired limits.

- See more at: https://www.testequipmentconnection.com/38540/Sencore_LC103.php#sthash.Tuoaf1fJ.dpuf

Company Information:

The Worlds Largest Distributor of New, Refurbished, and Second Hand Electronic Test and Measurement (T&M) Equipment.

Lake Mary, Florida, USA

Equipment Dealer / Broker / Auctions, Manufacturer

  • Phone 407-804-1299
  • Fax 407-804-1277

See Supplier Website »

Company Postings:

(3842) used SMT equipment marketplace items

(69) products in the catalog

(26) news releases

SMT Equipment & PCB Assembly Machines RFQ

This Sencore LC103 has been added in 16 Mar 2016

This Sencore LC103 has been viewed 200 times.

Industry 4.0 Reflow Oven

ICT Total SMT line Provider