SMT, PCB Electronics Industry News
  • SMTnet
  • »
  • Industry News
  • »
  • CableEye® Tester Calibration Verification Board, CB50 - Takes the Guesswork out of Scheduling Calibration

CableEye® Tester Calibration Verification Board, CB50 - Takes the Guesswork out of Scheduling Calibration

Feb 05, 2016

A simple method that allows quality-focussed companies to carry out periodic verification of tester calibration.

A simple method that allows quality-focussed companies to carry out periodic verification of tester calibration.

CAMI Research Inc. (Acton, MA) announces a new board for its CableEye cable and harness testing systems. Populated with precision resistors, it allows users to determine empirically whether the tester requires calibration. The CB50 may be used on all CableEye models.

Configuration

A leader in development of PC-based Cable & Wire Harness Test Systems for over 20 years, CAMI offers the CableEye suite of Low and High Voltage products complete with accessories including connector boards. The CB50 attaches to the tester like a regular connector board. When checking expansion modules, the board can be connected directly or via an extension cable.

Sold as a SINGLE board, the CB50 contains a network of precision resistors for checking resistance, and two diodes for checking diode polarity. Ten different resistance values are checked in triplicate at each of the tester header’s 64 test points. The values span the entire test range. The CB50 is configured to verify model M3U, while the CB50H is configured for models M3UH, HVX, and HVX-21.

Application

The CB50 is intended for periodic verification of tester calibration. To ensure that resistance measurements remain accurate, CAMI recommends yearly calibration. However, depending on environmental conditions and usage, testers may need calibrating more or less frequently. Certain components within models M3U, M3UH, HVX, and HVX-21 (i.e. those capable of measuring resistance) are analog components whose characteristics change slightly over time. This aging is a natural phenomenon common to all electronic components and may cause resistance measurements or gradually deviate from normal. A tester that is out of calibration will give inaccurate results. Some (maybe all) resistance measurements will be incorrect. Consequently, it may Pass what should Fail and, conversely, Fail what should Pass. In other words product yield will be contaminated due to unreliable quality.

Companies interested in quality product and maximum yield will ensure their testers are calibrated. Those with quality certifications such as six sigma or ISO9001 will be required to calibrate. The CB50 will allow these quality-focussed companies to optimally determine when calibration is necessary and to schedule accordingly. Customers may purchase a kit to calibrate the tester themselves, or send the tester to CAMI for calibration.

Warranty

Connector boards are included in CableEye’s standard, renewable one-year warranty of the tester for which it was purchased. The warranty covers replacement of worn connectors and cleaning of connector boards.

Availability & Domestic US Pricing

Available immediately, a CB50 is $195 (Item 780), and a CB50H is $205 (Item 780H).

Contact sales@camiresearch.com or +1 (978) 266-2655 for a quote.

Note: Prices are USA only and subject to exchange rates, freight and import costs. Contact your local authorised distributor for local pricing.


CAMI Research produces expandable and upgradable diagnostic Cable & Harness Test Systems for assembly, prototyping, production, and QC of standard or custom cables. CableEye® Testers display, and document basic electrical properties such as continuity, resistance, dielectric breakdown, insulation resistance, miswires, and intermittent defects.

Apr 28, 2022 -

CAMI Research Releases M2Z Low Voltage Multi-Conductor Cable Tester at EWPTE, Milwaukee

Dec 17, 2021 -

Generic Custom Test Interface Fixture Rated to 2100 Vdc, CB8H For Panel- and Cable-Mounted Connectors, and LIF Test Blocks

Sep 13, 2018 -

CAMI Celebrates 25 Years Developing Automation-Ready Cable and Harness Testers

Aug 21, 2018 -

CAMI Develops Capability of Checking Twist Pair Relationships in Cables as Short as Six Feet

Mar 21, 2018 -

CAMI Research to Host Professional Development Workshops at EWPT Expo, Milwaukee

Jan 11, 2018 -

CableEye® HV-Rated QuickMount™ Housing for CAMI Connector Boards, CBH2

Aug 01, 2017 -

CableEye® USB Type-C Test Fixture, CB26U

Jul 27, 2017 -

CAMI Research Releases CableEye® USB Type-C Test Fixture, CB26U

Mar 16, 2017 -

CAMI Research Re-Releases Continuity-Testing Video Tutorial Series

Feb 28, 2017 -

CAMI Research to Host Continuity & HiPot Testing Seminar & Training Sessions at WPT Expo, Milwaukee

14 more news from CAMI Research Inc. »

Jul 06, 2022 -

Offline PCBA Cleaning Machine HJS-7100,rosin flux, non-clean flux,water-soluble flux cleaning machine

Jul 05, 2022 -

Semiconductor Spray Cleaning Machine HJS-9700,Semiconductor Wafer Cleaning Machine HJS-9700

Jul 04, 2022 -

Pneumatic Stencil Cleaner HJS-9000II,dual chamber stencil cleaning machine

Jul 03, 2022 -

Electric Stencil Cleaner HJS-9500, SMT Electric Stencil Cleaner HJS-9500

Jul 01, 2022 -

Screen Cleaning Machine HJS-4600, SMT Screen Cleaning Machine HJS-4600

Jun 30, 2022 -

Electric Fixture Cleaning Machine HJS-6700, SMT pallet cleaning machine, soldering pallet cleaning machine

Jun 29, 2022 -

Waste Water Treatment Machine RWT-1000, SMT Waste Water Treatment Machine RWT-1000

Jun 28, 2022 -

Gen3's Dr Chris Hunt, CTO submits an insightful paper to the journal of Surface Mount Technology

Jun 28, 2022 -

Squeegee Cleaning Machine HJS-3700,SMT Squeegee Cleaning Machine HJS-3700

Jun 27, 2022 -

Solderstar Celebrates 20 Years of Innovation

See electronics manufacturing industry news »

CableEye® Tester Calibration Verification Board, CB50 - Takes the Guesswork out of Scheduling Calibration news release has been viewed 800 times

  • SMTnet
  • »
  • Industry News
  • »
  • CableEye® Tester Calibration Verification Board, CB50 - Takes the Guesswork out of Scheduling Calibration
 Reflow System

SMT spare parts - Qinyi Electronics