JUKI 2050 machine failure solution

KE2050M Z-axis fault E620014 error handling method!
Suddenly heard the sound of the machine. The machine stopped the fault for the E620014Z axis drive alarm.
View the drive. For Z drive 1, the third light is on (flashing). The head protection switch is disconnected. Make sure that there is no obvious abnormality in the suction shaft, so the protection switch is pressed and the original return is still present. Think about it: for the first time to encounter all the Z-axis jump back to the origin. OK. Can be homing. So another one. A head jump back. The problem came out. Up and down, obviously feel tight. Get spare parts replacement. Turn on OK. After calibration production.
It is recommended that everyone: generally vulnerable. Easy to bad parts or to order inventory. To prepare for emergency. As if today, no spare parts replacement.
KE2050 machine can not be installed,
Status: Machine can not mount the base station MARK identification beyond the allowable range analysis:
1. Disable the switch after the restart 2. Check the head, OCC line 3. Adjust the OCC brightness 4. For IPC-X3 CTL BOARD
5.OCC / LASER / HEAD OFFSET correction 6. For SAFTY CTL BOARD
7. Check the MSP CTL parameter to change the reference frame MARK range from "0" to "5000, 3000".
Z3 axis error, return to origin failed.
Sudden error in production prompt: Z3 axis error, return to the origin failed. To solve as follows:
1. Found the top of the substrate on the patch, control the third head of the light-emitting diode is not bright, manually move the nozzle to the sensor position, the diode is still not bright. 2. The Z4, Q4 and Z3, Q3 plug-on, still prompted: Z3 axis error, return to the origin of failure. 3. The patch on the head line to see and found a not plugged in, plugged in after the boot, the fault remains the same. 4. Finally found that the substrate has a insurance trip, manually press, restart the machine ---- OK. Professional and technical issues, please contact the phone, 18123970478, www.laiji.com.cn
2050 frequent collision to solve matters
KE2050M in the production process frequent collision. Solution:
1. Turn off the UPS, fault, still.
2. Measure the voltage is normal., After testing, are normal.
3. Measure the winding resistance of the X motor and confirm that it is normal.
4. In the OPEN COVER state, WARM UP, confirm that the sound is over there. Is the X-axis belt to make a sound.
5. Adjust the X-axis (large belt) tension, MSP parameter HEAD OFFSET correction .UPS normal use.
6. Re-produce, confirm troubleshooting /
R at E620015 when returning to the origin.
R Head in the homing E620015 error. Causes R Head can not return to the original solution:
Check the connection of the θ5 cable and reconnect the connection .Z3 Driver's connection line to confirm the fixed. Reboot problem remains the same. Then the θ5 line and other machines on the θ5 line to change the problem remains the final Z3 Driver and other machines For the change. The fault has not been transferred. Note that the line and Driver no problem. So can be judged as θ5 MOTOR problem,The problem be solved after change it.

---Becky Su
becky@hysmt.cn

View Juki JUKI 2050 machine failure solu

Company Information:

ZK Electronic Technology Co., Limited professional in Surface-Mount Technology area and supports most major brands of electronic asembly equipments with a large selections of compatible SMT.

Shenzhen, China

Consultant / Service Provider, Distributor, Equipment Dealer / Broker / Auctions, Manufacturer

  • Phone 86-0755-27807792
  • Fax 86-0755-22144952

See ZK Website »

Company Postings:

(18) used SMT equipment marketplace items

(5095) SMT parts, accessories & PCB supplies items

(70) products in the catalog

(1) technical library article

(2) news releases

SMT Equipment & PCB Assembly Machines RFQ

This Juki JUKI 2050 machine failure solution has been added in 06, Jun 2022

This Juki JUKI 2050 machine failure solution has been viewed 323 times.

Sell Your Used SMT & Test Equipment

Inline Cleaning Machine Hydro-clean Array