Divergence in Test Results Using IPC Standard SIR and Ionic Contamination Measurements

Published:

July 13, 2017

Author:

K. Tellefsen, M. Holtzer, T. Cucu, M. Liberatore, M. Schmidt - Alpha Assembly Solutions, S. Moser, L. Henneken, P. Eckold, U. Welzel, R. Fritsch, D. Schlenker - Robert Bosch GmbH

Abstract:

Controlled humidity and temperature controlled surface insulation resistance (SIR) measurements of flux covered test vehicles, subject to a direct current (D.C.) bias voltage are recognized by a number of global standards organizations as the preferred method to determine if no clean solder paste and wave soldering flux residues are suitable for reliable electronic assemblies. The IPC, Japanese Industry Standard (JIS), Deutsches Institut fur Normung (DIN) and International Electrical Commission (IEC) all have industry reviewed standards using similar variations of this measurement. (...)

This study will compare the results from testing two solder pastes using the IPC-J-STD-004B, IPC TM-650 2.6.3.7 surface insulation resistance test, and IPC TM-650 2.3.25 in an attempt to investigate the correlation of ROSE methods as predictors of electronic assembly electrical reliability....

  • Download Divergence in Test Results Using IPC Standard SIR and Ionic Contamination Measurements article
  • To read this article you need to have Adobe PDF installed

You must be a registered user to talk back to us.

 

Company Information:

See Company Website »

Company Postings:

(5) technical library articles

  • Apr 11, 2022 - iNEMI Webinar 07.07.2021 - PCB Cleaning | ZESTRON Americas
  • Jan 28, 2022 - Open Radio Unit White Box 5G | Whizz Systems
  • Nov 10, 2021 - Understanding the Cleaning Process for Automatic Stencil Printers | ITW EAE
  • Oct 20, 2021 - PCB Surface Finishes & The Cleaning Process - A Compatibility Study | ZESTRON Americas
  • Oct 06, 2021 - Cleaning Before Conformal Coating | ZESTRON Americas
  • Browse Technical Library »

Divergence in Test Results Using IPC Standard SIR and Ionic Contamination Measurements article has been viewed 757 times

  • SMTnet
  • »
  • Technical Library
  • »
  • Divergence in Test Results Using IPC Standard SIR and Ionic Contamination Measurements
FPC* - Fluid Pressure Control - Dispensing Pump

Sell Your Used SMT & Test Equipment